Safety Non-contact Door Switch, Magnetic, M12 Cable connector type, 24VDC, IP67
Unit of Measure

Specifications

Brands

N/A Autonics USA

Weight

N/A 0.2 lb

Availability

N/A 2

Direct Current (DC) Voltage Power Supply

N/A 24 V

Tolerance (±)

N/A 10 %

Material

N/A Body CAP: PC

Protection Structure

N/A Ingress Protection (IP) 67 (International Electrotechnical Commission (IEC) Standard)

Approximate Weight

N/A 58.1 g71.6 g

Protection Circuit

N/A Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit

Approval

N/A Canadian Underwriters Laboratories (CULUS) Conformite Europeenne (CE) Technical Inspection Association (TUV)

Insulation Resistance

N/A Less than 50 Megaoham (500 VDC , megger)

Alternating Current (AC) Volatge Dielectric Strength

N/A 1500 V

Dielectric Operating Frequency For 1 Minute

N/A 50 Hz60 Hz

Vibration

N/A 1.0 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours

Shock

N/A 300 m/s² (approx. 30G) in each X, Y, Z direction for 3 times

Connection

N/A Cable connector type

Power Consumption

N/A 400 mA

Operation Indicator

N/A OFF: Red ON: Green

Connector Type

N/A M12 Connector

Ambient Temperature

N/A -10 to 55 ºC

Storage Ambient Temperature

N/A -20 to 60 ºC

Relative Humidity (RH)

N/A 35 to 85 %

Non-freezing or Non-condensation Relative Humidity (RH)

N/A 35 to 85 %

Life Expectancy

N/A Less than equal to 20,000,000 times (with low load)

Sub Output

N/A PNP open collector output - 24 VDC, 10 mA

Operation Distance - Off to On

N/A Greater than 5 mm

Operation Distance - On to Off

N/A Less than 15 mm

Operating Frequency

N/A 100 Hz

Vibration - Malfunction

N/A 1.0 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 10 min

Shock - malfunction

N/A 300 m/s² (approx. 30G) in each X, Y, Z direction in output ON/OFF status for 3 times