Safety Light Curtains, Advanced type, Through-beam, 15 M Sensing distance, 75 pcs & 25 mm Optical a.
Unit of Measure

Specifications

Brands

N/A Autonics USA

Sensing Type

N/A Through-Beam

Light Source

N/A Infrared Light Emitting Diode (LED)

Light Source Wavelength

N/A 855 nm

Effective Aperture Angle (EAA) within (when the Sensing Distance is Greater than 3 Meter (m) for both Emitter and Receiver) (±)

N/A 2.5 º

Sensing Distance

N/A 15 m

Note for Sensing Distance

N/A Short - Long Mode (Setting Switch or Atlightcurtain)

Short Mode

N/A 0.2 to 8 m

Long Mode

N/A 0.2 to 15 m

Detection Capability Diameter (Hand-Body)

N/A 30 mm

Sensing Target

N/A Opaque

Number of Optical Axes or Pieces

N/A 75

Optical Axis Pitch

N/A 25 mm

Maximum Series Connection Set

N/A 4

Series Connection Optical Axes

N/A ≤ 400

Direct Current (DC) Voltage

N/A 24 V

Direct Current (DC) Voltage Tolerance (±)

N/A 20 %

Maximum P to P Ripple Factor

N/A ≤ 10 %

Current Consumption (Emitter)

N/A ≤ 106 mA

Current Consumption (Receiver)

N/A ≤ 181 mA

Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Safety Related Output except for the Residual Voltage)

N/A 24 V

Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Safety Related Output except for the Residual Voltage)

N/A 24 V

Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Auxiliary Output 1 and 2)

N/A ≤ 24 V

Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Auxiliary Output 1 and 2)

N/A ≤ 24 V

Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Lamp Output 1 and 2)

N/A ≤ 24 V

Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Lamp Output 1 and 2)

N/A ≤ 24 V

Protection Circuit

N/A Output Short-circuit Over-current Protection Reverse Output Polarity Reverse Power Polarity

Safety-Related Functions

N/A Blanking (Fixed Blanking and Floating Blanking) External Device Monitoring (EDM) Interlock (Reset Hold) Muting/Override Reduced Resolution

General Functions

N/A Alarm for Reduction of Incident Light Level Mutual Interference Prevention Self-Test

Others Functions

N/A Change of Sensing Distance External Test (Light Emission Stops), Auxiliary Output (AUX 1, 2), Lamp Output (LAMP1, 2) Switching to NPN or PNP

Synchronization Type

N/A Timing Method by Synchronous Line

Insulation Resistance at 500 Volt (V) Direct Current (DC) Megger Voltage

N/A 20 MΩ

Noise Immunity

N/A The Square Wave Noise (Pulse Width: 1㎲) by the noise simulator ± 240VDC

Dielectric Strength Alternating Current (AC) Voltage Between Power off Terminals (At 50/60 Hertz (Hz) Frequency for 1 Minute)

N/A 1000 V

Vibration

N/A 0.7 mm amplitude at frequency of 10 to 55Hz (for 1 min), 20 sweeps in each X, Y, Z direction

Approximate Shock in Each X,Y,Z Direction for 1000 Times

N/A 100 m/s²10 g

Pulse Width in Each X, Y, Z Direction for 1000 Times

N/A 16 ms

Maximum Environment Ambient Received Illumination (Sunlight)

N/A 10000 lx

Maximum Environment Ambient Received Illumination (Incandescent Lamp)

N/A 3000 lx

Ambient Temperature (Non-Freezing or Non-Condensation)

N/A -10 to 55 ºC

Ambient Storage Temperature (Non-Freezing or Non-Condensation)

N/A -20 to 70 ºC

Environment Ambient Relative Humidity (RH) (Non-Freezing or Non-Condensation)

N/A 35 to 85 %

Environment Ambient Storage Relative Humidity (RH) (Non-Freezing or Non-Condensation)

N/A 35 to 95 %

Protection Structure

N/A Ingress Protection (IP) 65 (International Electrotechnical Commission (IEC) Standard) Ingress Protection (IP) 67 (International Electrotechnical Commission (IEC) Standard)

Case Material

N/A Aluminum

Front Cover Material

N/A Polymethyl Methacrylate

Sensing Part Material

N/A Polymethyl Methacrylate

End Cap Material

N/A Polycarbonates (PC)

Cable Material

N/A Polyurethane (PUR)

Approval

N/A European Conformities (CE) Technical Inspection Association (TUV) Underwriters Laboratory for Canada and United States (cULus)

International Standards

N/A Canadian Standards Association (CSA) C22.2 No. 14 International Electrotechnical Commission (IEC)/European Standards (EN) 61496-1 (Type 4, ESPE) International Electrotechnical Commission (IEC)/European Standards (EN) 61496-2 (Type 4, AOPDs) International Electrotechnical Commission (IEC)/European Standards (EN) 61508-1~-7 (SIL 3) International Electrotechnical Commission (IEC)/European Standards (EN) 62061 (Safety Integrity Level, Claim Limit (CIL CL 3)) International Organization for Standardization (ISO) 13849-1 (PL e, Cat. 4) International Organization for Standardization (ISO) 13849-2 (PLe, Cat. 4) Underwriters' Laboratories (UL) 508 Underwriters' Laboratories (UL) 61496-1 (Type 4, ESPE) Underwriters' Laboratories (UL) 61496-2 (Type 4, AOPDs)

Weight

N/A 0.2 lb

Applications

N/A Safety

Note

Note

N/A
  • Current consumption, Response time: It may differ depending on the models. For more information, see the "SFL/SFLA User Manual."
  • Load voltage of Safety related output: The values of load voltage were drawn with PNP output, and in case of NPN output, apply these in reverse.
  • Load current of Safety related output: Be sure that the load current should be greater than 6 mA
  • Residual voltage of Safety related output: The residual voltage was drawn with 300 mA of load current.
  • Auxiliary output, Lamp output: It is the non-safety output. Do not use it for safety purposes.