Safety Light Curtains, Advanced type, Through-beam, 15 M Sensing distance, 72 pcs & 25 mm Optical a.
Unit of Measure
Specifications
Brands |
N/A Autonics USA |
Sensing Type |
N/A Through-Beam |
Light Source |
N/A Infrared Light Emitting Diode (LED) |
Light Source Wavelength |
N/A 855 nm |
Effective Aperture Angle (EAA) within (when the Sensing Distance is Greater than 3 Meter (m) for both Emitter and Receiver) (±) |
N/A 2.5 º |
Sensing Distance |
N/A 15 m |
Note for Sensing Distance |
N/A Short - Long Mode (Setting Switch or Atlightcurtain) |
Short Mode |
N/A 0.2 to 8 m |
Long Mode |
N/A 0.2 to 15 m |
Detection Capability Diameter (Hand-Body) |
N/A 30 mm |
Sensing Target |
N/A Opaque |
Number of Optical Axes or Pieces |
N/A 72 |
Optical Axis Pitch |
N/A 25 mm |
Maximum Series Connection Set |
N/A 4 |
Series Connection Optical Axes |
N/A ≤ 400 |
Direct Current (DC) Voltage |
N/A 24 V |
Direct Current (DC) Voltage Tolerance (±) |
N/A 20 % |
Maximum P to P Ripple Factor |
N/A ≤ 10 % |
Current Consumption (Emitter) |
N/A ≤ 106 mA |
Current Consumption (Receiver) |
N/A ≤ 181 mA |
Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Safety Related Output except for the Residual Voltage) |
N/A 24 V |
Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Safety Related Output except for the Residual Voltage) |
N/A 24 V |
Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Auxiliary Output 1 and 2) |
N/A ≤ 24 V |
Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Auxiliary Output 1 and 2) |
N/A ≤ 24 V |
Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Lamp Output 1 and 2) |
N/A ≤ 24 V |
Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Lamp Output 1 and 2) |
N/A ≤ 24 V |
Protection Circuit |
N/A Output Short-circuit Over-current Protection Reverse Output Polarity Reverse Power Polarity |
Safety-Related Functions |
N/A Blanking (Fixed Blanking and Floating Blanking) External Device Monitoring (EDM) Interlock (Reset Hold) Muting/Override Reduced Resolution |
General Functions |
N/A Alarm for Reduction of Incident Light Level Mutual Interference Prevention Self-Test |
Others Functions |
N/A Change of Sensing Distance External Test (Light Emission Stops), Auxiliary Output (AUX 1, 2), Lamp Output (LAMP1, 2) Switching to NPN or PNP |
Synchronization Type |
N/A Timing Method by Synchronous Line |
Insulation Resistance at 500 Volt (V) Direct Current (DC) Megger Voltage |
N/A 20 MΩ |
Noise Immunity |
N/A The Square Wave Noise (Pulse Width: 1㎲) by the noise simulator ± 240VDC |
Dielectric Strength Alternating Current (AC) Voltage Between Power off Terminals (At 50/60 Hertz (Hz) Frequency for 1 Minute) |
N/A 1000 V |
Vibration |
N/A 0.7 mm amplitude at frequency of 10 to 55Hz (for 1 min), 20 sweeps in each X, Y, Z direction |
Approximate Shock in Each X,Y,Z Direction for 1000 Times |
N/A 100 m/s²10 g |
Pulse Width in Each X, Y, Z Direction for 1000 Times |
N/A 16 ms |
Maximum Environment Ambient Received Illumination (Sunlight) |
N/A 10000 lx |
Maximum Environment Ambient Received Illumination (Incandescent Lamp) |
N/A 3000 lx |
Ambient Temperature (Non-Freezing or Non-Condensation) |
N/A -10 to 55 ºC |
Ambient Storage Temperature (Non-Freezing or Non-Condensation) |
N/A -20 to 70 ºC |
Environment Ambient Relative Humidity (RH) (Non-Freezing or Non-Condensation) |
N/A 35 to 85 % |
Environment Ambient Storage Relative Humidity (RH) (Non-Freezing or Non-Condensation) |
N/A 35 to 95 % |
Protection Structure |
N/A Ingress Protection (IP) 65 (International Electrotechnical Commission (IEC) Standard) Ingress Protection (IP) 67 (International Electrotechnical Commission (IEC) Standard) |
Case Material |
N/A Aluminum |
Front Cover Material |
N/A Polymethyl Methacrylate |
Sensing Part Material |
N/A Polymethyl Methacrylate |
End Cap Material |
N/A Polycarbonates (PC) |
Cable Material |
N/A Polyurethane (PUR) |
Approval |
N/A European Conformities (CE) Technical Inspection Association (TUV) Underwriters Laboratory for Canada and United States (cULus) |
International Standards |
N/A Canadian Standards Association (CSA) C22.2 No. 14 International Electrotechnical Commission (IEC)/European Standards (EN) 61496-1 (Type 4, ESPE) International Electrotechnical Commission (IEC)/European Standards (EN) 61496-2 (Type 4, AOPDs) International Electrotechnical Commission (IEC)/European Standards (EN) 61508-1~-7 (SIL 3) International Electrotechnical Commission (IEC)/European Standards (EN) 62061 (Safety Integrity Level, Claim Limit (CIL CL 3)) International Organization for Standardization (ISO) 13849-1 (PL e, Cat. 4) International Organization for Standardization (ISO) 13849-2 (PLe, Cat. 4) Underwriters' Laboratories (UL) 508 Underwriters' Laboratories (UL) 61496-1 (Type 4, ESPE) Underwriters' Laboratories (UL) 61496-2 (Type 4, AOPDs) |
Weight |
N/A 0.2 lb |
Applications |
N/A Safety |